Pro Convert Support

Check these topics to find answers to your questions or learn more about the Pro Convert

All
All
Get Started
Settings
Troubleshooting

How to configure Pro Convert via Web UI

Pro Convert allows you to set up and control it via a web-based user interface as an administrator account or a general user. You can get access to the Web UI using either NDI® Studio Monitor or USB RNDIS. Make sure that at least one of the following web browsers is equipped in your system. Microsoft Internet Explorer 11 Microsoft Edge Mozilla Firefox version 61 and above Google Chrome version 49 and above Apple Safari 11.1 and above Opera 55.0.2994.44 and above Method Ⅰ: Using USB RNDIS to configure Pro Convert For Mac users who are connecting via USB RNDIS for the first time, please download and install a RNDIS driver (like HoRNDIS) before connecting the USB cable. Connect your converter to your computer via a USB cable. Run your web browser, and type in USB RNDIS address to access the Web UI. The default address is http://192.168.66.1. Enter your account and password in the SIGN IN page, and configure the device after you login successfully. The default administrator account and password (case-sensitive) are as follows. Username: Admin Password: Admin Method Ⅱ: Using File Explorer to configure Pro Convert (For Windows) Open a File Explorer window. Select the Network, and turn on the network discovery function if a prompt window appears. Find your Pro Convert device in the Other Device section, where the detected device will be shown as "Pro Convert + #board index + (serial number)". Double click the converter icon to open the Web UI in your web browser. Enter your account and password in the SIGN IN page. The default administrator account and password (case-sensitive) are as follows. Username: Admin Password: Admin Method Ⅲ: Using NDI® Studio Monitor to configure Pro Convert From a computer in the same LAN, download and install Studio Monitor from NewTek official site https://www.newtek.com/ndi/tools for free. Launch Studio Monitor in your system. Click the Menu icon at the top left, and then choose your NDI® channel: device name > source name. Click the gear icon at the bottom right. Then the web UI of your chosen device pops up in your web browser. Enter your account and password in the SIGN IN page, and configure the device after you login successfully. The default administrator account and password (case-sensitive) are as follows. Username: Admin Password: Admin

Article ID: 005030002

How to change device name and source name

Pro Convert allows you to set up and control via a web-based user interface as either an administrator or a general user. Changing the device name requires administrator rights, while changing the source name only requires general user rights. This article illustrates how to change the device name and source name via an administrator account. A general user account can only change the video source name, steps of which are the same as those an administrator dose. 1Access the Web UI, and sign in as administrator For instructions on how to access the Pro Convert Web UI, see how to configure Pro Convert via Web UI. 2Change Source name Click the NDI® tab. Change Source name. The default source name is #%board-id% (%serial-no%). board-id indicates the unit's rotary switch number. You can change the board-id via the rotary switch in your unit. serial-no indicates the unit's serial number labeled on its surface. %board-id% and %serial-no% are the only supported variables. You can change the source name to a string with maximum of 30 case-sensitive characters, which contains A to Z, a to z, 0 to 9, spaces and special characters like _-#()%. If you leave the source name empty, it will be filled in with the default value #%board-id% (%serial-no%) automatically after clicking Apply. Click Apply to save changes. 3Change device name Click the System > Network tab. Change Device name. The device name is a string of 1 to 30 non-case sensitive characters, containing letters a to z, A to Z, 0-9, spaces and special characters like _-+. Click Apply to save changes. Click Yes in the prompt dialog box. It may take a few minutes to make your settings take effect. 4Verify your settings Click the Dashboard tab in the Web UI, check Device name, and Name in NDI® > General section. Or open the NDI® Studio Monitor (click here to download the NDI tool). Then check the device name > NDI® stream channel. (See the picture below)

Article ID: 005020003

What to do if I forget the password of Pro Convert device

We can't help you retrieve your password if you forget it. However, you can create a new password instead. If you are a general user, ask your administrator to assign a new password for you. If you are the administrator, you need to reset all settings to default values, then set a new admin password. 1Forget the general user password Access the Web UI, and sign in as administrator. For instructions on how to access the Pro Convert Web UI, see how to configure Pro Convert via Web UI. Click the System tab. Click Set password, which appears when you approach the cursor to your user name. Type in a new password, and confirm it in the prompt window. The password is a string of 1 to 32 case-sensitive characters, which contains A-Z, a-z, 0-9 and special characters _-~!@#$%^&*-+=. Click OK. 2Forget the admin password Connect the device and your computer via a USB cable. Launch your web browser, and type in the USB RNDIS address to access the Web UI SIGN IN page. The default IP address of USB RNDIS is http://192.168.66.1. Please do not modify it unless there is a conflict in your network. Click Reset all settings in the top right corner of the SIGN IN page. The reset process may take a few minutes. Sign in the Web UI with default admin account (case-sensitive): Admin, Admin. Click and enter System tab. Click Set password appeared when you approach the cursor to your user name. Type in new password, and confirm the new password in the prompt window. The password is a string of 1 to 32 case-sensitive characters, which contains letters A-Z, a-z, numbers 0-9 and special characters _-~!@#$%^&*-+=. Click OK.

Article ID: 005020006

How to set the IP address for Pro Convert

中文版 In a DHCP-enabled LAN, the Pro Convert device is plug-and-play Connect the converter to Ethernet network and power it up, then the unit will be assigned an IP address automatically, and the device is ready to work. To have great control on the device, like changing encoding/decoding parameters, you need to use the Web UI. Do the following steps to open the Web UI. For Linux and MacOS users, refer to the non-DHCP network operations below to get access to the Web UI and log in, then you can configure the device and monitor device status. For Windows user, do the following steps to open the Web UI: Open a File Explorer window. Select the Network, and turn on the network discovery function if a prompt window appears. Find your Pro Convert device in the Other Device section, where the detected device will be shown as "Pro Convert + #board index + (serial number)". Double click the converter icon to open the Web UI in your web browser. After logging in successfully, you can do the configurations and monitor device status. If you forgot the password, click Reset all settings at the top-right corner of the SIGN IN page to set all parameters back to the default values, then you can log in with the default administrator account (case-sensitive): Username: Admin Password: Admin Note that the reset option is only available when connecting the convert directly to the PC via USB RNDIS. In a non-DHCP LAN, you will have to set IP address manually in the Web UI Get access to the Web UI via USB RNDIS a. Connect your computer and your device. b. Type http://192.168.66.1 in your web browser to log in. If you can’t see the SIGN IN page, do the following steps to find the RDNIS IP address. Linux Launch the terminal. Type in "ifconfig -a", and find an IPv4 address of the form 192.168.xxx.2. MacOS Launch the System Preferences. Choose Network > Pro Convert, and check its IP Address. Windows Type "cmd" in the search bar to start the command interpreter. Type in "ipconfig", and find an IPv4 address of the form 192.168.xxx.2. If 192.168.xxx.2 is taken, the IP address would automatically change to another value within the ranges of 192.168.xxx.2 to 192.168.xxx.254. Login Sign in using the default administrator account (case-sensitive). Username: Admin Password: Admin If you forgot the password, click Reset all settings at the top-right corner of the SIGN IN page to set all parameters back to the default values, then you can log in with the default administrator account. The reset option is only available when connecting the convert directly to the PC via USB RNDIS. Set IP address manually a. After logging in with an admin account, go to System > Network. b. Turn on Set IP Address Manually, and then enter a new IP address, Subnet mask, Gateway, and DNS server. The IP address must be within the same network segment with your PC. c. Click Apply to save changes. Reference For the latest Pro Convert products, please visit our official website: https://www.magewell.com/pro-convert. For the list of NDI-enabled software, please refer to http://www.magewell.com/compatible-software.

Article ID: 005020010

1
2
Load More