The device supports directly pasting the ZIXI platform URL, and it will automatically parse and add the data source. Alternatively, you can manually specify the parameters.
- Protocol Type: Set the protocol type to ZIXI Pull.
- Name: Default is ZIXI Server. You can specify a name for the task to manage multiple servers easily. (Supports 1-63 characters including A-Z, a-z, 0-9, spaces, special characters: ._-+'[]() and cannot start or end with a space.)
- Host: Enter the IP address or domain name of the ZIXI Pull host.
- Port: Default is 2077, valid range is 1-65535.
- Stream ID: The unique ID for identifying the stream. Required field. Range: 1 - 127 characters, case-sensitive.
- Password: Enter the password for the ZIXI server to authenticate the stream. Range: 0 - 127 characters.
- Latency: Range is 20 ~ 5000ms, default is 200ms. It is recommended to keep the delay time consistent between the receiving and sending sides.
- Minimize Latency: Enable dynamic latency. Zixi supports dynamic delay, adjusting automatically based on network conditions. Suitable for non-live sports broadcasting.
- Ignore TLS Certificate Errors: Check to ignore TLS (Transport Layer Security) certificate errors. Default is disabled.
- Decryption Mode: Not used by default. Supports AES encryption for stream data security. AES-128/192/256 encryption is supported. You must specify the Decryption Key (10-79 characters). The same key must be used on both the sending and receiving ends for successful decryption.
- Buffer Duration: Range is 1 ~ 5000ms, default is 60ms. It is recommended that the delay time of the decoder be consistent with that of the stream sender.
- Hotkey: Disabled by default. Once configured, you can switch data sources quickly through the keyboard hotkeys connected to the decoder. This feature is disabled if the Profile function is enabled.
- Audio Track: Default 1, optional 1–8 tracks.
- TS ProgID: Program ID (Program Number) is an identifier that represents a logical program (service) within an MPEG Transport Stream, range 1–10000000, default empty.
- OK: Save the current settings.